Technical Data 15m Truck Spraybooth YS-15-50

Internal Size

15000mm X 5000mm X 5000mm

External Size

15144mm X 6896mm X 5600mm

Basement

No basement as per picture, the booth mounts on a concrete slab.

Main Door

1 x set 4000mm X 4500mm, Galvanised steel frame, with (EPS) polystyrene inside.

Escape Door

1 x 800mm X 2000mm (W x H)

Room Body

Profiles beams in the roof to strengthen the room body. Wall panel thickness 70mm, width 1150mm tongue and groove structure, 0,476mm colour steel with (EPS) polystyrene insulation inside.

Lighting System

Ceiling Lights 18 units x 4pcs = 72 tubes x 36w per tube. Side Wall lights 22 units x 4pcs = 88 tubes x 36w per tube.

Intake Air System

2 x intake units totaling 4 x 7.5KW double intake centrifugal fans for intake air, air capacity is 21000m3 for each fan totaling 84000m3 per hour.

Exhaust Air System

2 x 11KW double intake centrifugal fans for exhaust air, with motor outside, belt-drive. Air capacity is 36000m3/h for each fan, totaling 72000m3/h. Exhausts equiped with a manual dampers for exhaust air.

Heating System

2 x units Riello RG5S oil burners 520000Kcal/h, stainless steel combustion chambers and pneumatic dampers to actuate from spraying to baking cycle.

Filtering System

Pre-filters, high efficiency filter(ceiling filter), exhaust fiberglass filter.

Roof Plates

50mm thick EPS heat preservation panels.

Control System

Spraying, Heat Spraying and Baking function controls, time setting, lighting switch, failure indicator, thermostat, power supply switch, emergency stop switch, Ampere meter, Volt meter, hours meter, temperature limit controler, pressure gauge.

Frequency of Air Exchange

223 times per hour

Maximum Working Temperature

80  by Browse to Save">Degrees Celcius

Illumination

>1200 Lux

Noise Levels

<85 dB